2
S&S® VFI Knock Sensor Kit and Replacement Parts
............. 106-0810
...............................55-1015
.................................................................... 106-1300
Note that the installation kit may vary slightly if purchased with a complete engine. Not all of the hardware used in the 106-0810 is required for specic
installations. This extra hardware will not be included in S&S engine packages.
WARNING
WARNING
CAUTION
KNOCK SENSOR MOUNTING
Prior to installation, disconnect and remove the battery, negative cable rst. This will eliminate potential sparks and inadvertent
engagement of the starter while working on the motorcycle.
Be careful not to damage the front of the tank when raising or removing it.
NOTE - Clearances are limited at the front of the tank. Use care not to damage any painted surfaces while handling tank.
The knock sensor must be mounted to the rear cylinder head for correct operation.
The knock sensor will provide an incorrect signal if mounted on the front cylinder head.
NOTE - There are two mounting locations possible for the knock sensor. Read the description of each location, and then examine your motorcycle for
which one to use. The rst location has better clearance than the second. The knock sensor will work well in either location.
Location 1:
sensor there. See Step a on next pageLocation 2.
Location 2:
See Step b on next page.